Your location:Home > Product > Large flow pump double suction pump series
Large flow pump double suction pump series

Centrifugal pump opened in S type single stage double suction pump housing

Category:Large flow pump double suction pump series
Number of views:218
QR code:


Add time:2025-04-09
Brief:

Type S single stage double suction pump housing open centrifugal pump for pumping clean water or other liquids similar to water in physical and chemical properties. The temperature of the liquid to be transported shall not be higher than 80℃. It is suitable for factories, mines, urban water supply, power stations, farmland drainage and irrigation and various water conservancy projects.

【 Product Overview 】

The suction inlet and leaf exit of the pump are under the axis of the pump, and are perpendicular to the axis into a horizontal direction. No need to remove the inlet and outlet water pipes and motors during maintenance. From the driving direction, the water pump rotates clockwise (it can also be changed to counterclockwise 旆 according to user needs). The main parts of the pump are: pump body, pump cover, impeller, shaft, double suction seal ring, shaft sleeve and so on. In addition to the grid material of the shaft is carbon steel, the other main parts are made of cast iron.

【 Product use 】

Type S single stage double suction pump housing open centrifugal pump for pumping clean water or other liquids similar to water in physical and chemical properties. The temperature of the liquid to be transported shall not be higher than 80℃. It is suitable for factories, mines, urban water supply, power stations, farmland drainage and irrigation and various water conservancy projects.

【 Product structure 】

1

Pump cover

12

Bearing sleeve

2

Shaft

13

Bearing body gland

3

Double suction seal ring

14

Bearing body armour

4

Impeller

15

Pump coupling

5

key

16

key

6

Shaft sleeve

17

Garden nut

7

Packing sleeve

18

Single row radial ball bearing

8

Filler

19

Bearing end cap

9

Packing ring

20

Pump casing

10

Packing gland

21

Bearing body B

11

Shaft sleeve nut

 

 


【 Installation sequence 】

(1) Put the water pump and electric jia on the anchor screw check, put on the nut, and put on the concrete foundation reserved for the anchor bolt hole. By adjusting the wedge pad between the base, the level is corrected and the coaxiality of the motor shaft on the pump is calibrated. Then fill all the anchor holes with concrete.

(2) After the concrete is dry and solid, then check the coaxiality of the pump and the motor shaft. Calibration on the outer circle of the two couplings, the error is not more than 0.1mm. The non-uniformity tolerance of the end machine clearance along the circumference is 0.3mm. Check the calibration accuracy after tightening the anchor nut, and then fill the bottom of the motor and pump foot with concrete, but the wedge block must be left around.

(3) Check that the motor rotation is consistent with the pump, and install the coupling pin.

4. The inlet and outlet water pipes should be supported separately, and the pump body should not be supported.

5. the joint surface between the pump and the pipeline should be kept well sealed, especially the water inlet pipe must be strictly non-leaking, and there should be no possibility of storing air on the device.

6. If the water pump device is above the water level, the bottom valve should be installed in order to start the water. The method of pumping water can also be used.

The above is the installation method and requirements of the pump set without a common base. For the installation of the pump set with a common base, refer to the above method.

Product related documents:

If you would like to learn more about the centrifugal pump opened in the Model S single stage double suction pump housing, please click the link below to view

Performance parameter table of centrifugal pump opened in S type single stage double suction pump housingThe flow, head, power, efficiency and other data corresponding to each specification of centrifugal pump opened in S-type single stage double suction pump housing are introduced.

Installation dimensions of centrifugal pump opened in S-type single stage double suction pump housingThis paper introduces the installation dimensions and flange connection dimensions of different specifications of centrifugal pump opened in S-type single stage double suction pump housing.

Instructions for the use of centrifugal pump opened in S type single stage double suction pump housingThis paper introduces the matters needing attention in installation and use of centrifugal pump opened in S type single stage double suction pump housing and the common troubleshooting methods.

If you are interested in the centrifugal pump products in the Model S single stage double suction pump housing, please download the leftElectronic sample of centrifugal pump opened in S-type single stage double suction pump housing,So that you can check at any time!

 

HomeTelProduct
Links: Self-priming pump series Submersible sewage pump Submersible axial flow pump
Copyright © Hebei Yongquan Motor Pump Manufacturing Co., Ltd All Rights Reserved