Your location:Home > Product > Control cabinet Series
Control cabinet Series

Pump control cabinet

Category:Control cabinet Series
Number of views:256
QR code:


Add time:2025-04-10
Brief:

Product characteristics

A wide range of uses. For various applications, such as domestic water supply, fire, spray, pressurization, pressure regulation, hot and cold water circulation system (air conditioning joint control and boiler circulation system), industrial control pumps, sewage discharge, etc., there are corresponding models and specifications. Control motor function range 0.18-250kw.

● Good quality. From reasonable selection, domestic electrical components to the strict design and precision production considering the transition process of each switch state, is the difference between SBK series and general pump control cabinets.

● Various functions. One control one; One control two to one control four, the main and standby pump can choose a variety of starting methods, various control forms, automatic fault switching. It can also be specially designed.

AYK series promises quality, no worries.

Product overview

AYK series electrical control cabinet is Shanghai Aoyi Pump Manufacturing Co., Ltd. fully absorb the experience of domestic and foreign pump control, set many years of experience in pump application control, continuous optimization, after repeated demonstration, optimization of the line, the heart of the design. The product has complete functions, reliable and durable, and the cabinet is upright and beautiful. The product has short circuit, phase loss, overload protection and motor over temperature, leakage and other protection functions and complete status display. There are a series of submersible sewage pump control, in addition, it also has pump body leakage, stator winding overheating and other protection functions. It also has single pump and multi-pump control working mode, a variety of main and standby pump switching modes and various starting modes. All products with master and backup control have the function of shutting down the faulty pump and putting the standby pump into the pump by itself (the standby pump throws itself). It can be widely used in agricultural production and automatic control of water supply, drainage, fire fighting, spray pipe network pressurization and HVAC cold and heat circulation and other occasions.

AYK series electrical control cabinet has excellent internal quality, beautiful appearance, easy installation and operation, and is a reliable companion for all kinds of pumps.

Performance parameter

AYK electrical control cabinet selection tips

1. according to the use of the pump to determine the control type

● Not marked: liquid level control. For high water tank water supply, when the reservoir low water level to stop the pump, high water level of the high water tank to turn off the pump, the bottom water level to open the pump. The use of this type of high-performance KEY float switch equipped with Italian technology can reliably realize the automatic control of the water supply and drainage pump according to the change of liquid level height and bottom. Other level controllers can also be used.

P type: pressure control, with external electric contact pressure gauge or pressure controller, can be realized according to the change of pipe network pressure automatically open and close the pump. This type is widely used in domestic water supply and fire pressurization system, the application range is very wide.

● Type T: Temperature control. External temperature controller, pump on or off according to the set temperature range, used in constant temperature, heat exchange system.

Type S: According to the timing needs to control the opening and closing of the pump, suitable for a variety of timing or regular interval working mode control.

● Type X: Fire protection type. This type according to the national fire code design, fire, spray pump can be started: 1. Chassis panel manual; 2. Start each fire hydrant or pressure switch; 3. Fire center DC24V starts. And the pump sent to the fire center stop, open signal contact for indication.

● Type K: air conditioning pump control. This type is specially designed for air conditioning pump supporting products. The pump is opened by manual or control center linkage operation, the pump is running to output a control contact condition for the starting of the refrigeration unit, to achieve the control procedure of opening the pump first, and then opening the air conditioning to ensure operation.

●L type: submersible sewage type. According to the characteristics of submersible pump, this type in addition to the main circuit short, phase loss, overload protection also has pump body water leakage protection motor stator winding overheat protection and leakage protection.

2. determine the number of pumps controlled by the control cabinet, that is, the multi-pump control mode

● Single control is represented by "1"

● One control two (one with one standby) is represented by "2"

● One control three (two with one) is represented by "3"

● One control four (three with one standby) is represented by "4"

3. according to the main pump and standby pump operation mode to determine the switching mode

● Not marked: ordinary type

Select primary pump and standby pump with manual switch before starting. When the active pump fails, the standby pump is automatically put into operation. Generally, both the active and standby pumps can be controlled in this way.

●As: automatic switching/manual switching

It is suitable for the occasions when the main and standby pumps need to be regularly exchanged, so that the long-term continuous working time is evenly divided between the main and standby pumps, and the conventional switching time is 8/12 hours. When automatic switching is not required, the switch can be turned into manual switching mode to select the main and standby pumps. This model has the function of automatic switching of standby pumps.

●Ac: Alternating automatic switching/manual switching is suitable for the occasions when the main and standby pumps need to work in turn, and the main and standby pumps are exchanged once every time they are started. When there is no need to alternate, the transfer switch can also be used to manually switch to select the main and standby pumps. This model has the function of self-injection pump (fire, spray main pump can not choose this mode of operation).

4. the general motor power of 15KW below the pump using direct start.

●Z: Sewage pumps above 150kw generally use autobuck or soft start. Fire and spray pumps also use this starting mode

●Y: If there is no special requirement for the pump above 150kw, it is generally started by Y-△ step-down mode.

4. Interpretation of terms

▲ Manual start-stop: manual operation panel switch start-stop equipment;

▲ Automatic start and stop: by the system sensor (float, electric contact pressure gauge, etc.) or control center start and stop equipment;

▲ Remote start and stop: remote switch (manual pull) start and stop equipment;

▲ Manual alternations: select the main pump and standby pump by the panel pump switch;

▲ Timing alternations: suitable for continuous working system, the main pump and standby pump work alternately according to the equipment time interval, so that the continuous working time is evenly divided in the main and standby pump;

▲ Automatic alternation: suitable for continuous working system, the main pump and backup pump automatically alternate according to the start and stop of the equipment, so that the pump runs evenly;

▲ Backup pump: When the main pump fails, the backup pump is put into operation by itself.

5. SBK electrical control cabinet structure

The structure of the control cabinet is divided into loop part, control loop part and external accessory part.

Main loop: refers to the power input through the circuit breaker, contactor main contact, thermal relay main loop to the output terminal (connected to the motor) circuit.

Control circuit: The control circuit, protection circuit and display circuit from the signal receiving to the completion of the contactor switching on or off.

External accessories: high-seal float switch, electric contact pressure gauge, temperature meter, etc., for the realization of automatic working mode signal components.

6. Requirements of the applicable environment

The installation environment must meet the following requirements:

▲ Altitude ≤2000 meters;

▲ Ambient temperature < +400C;

▲ Environment no explosive dangerous medium, no enough to corrode metal and destroy insulation of damp gas and dust, the average monthly humidity ≤ 90% (250C);

▲ Vertical installation inclination ≤50;


HomeTelProduct
Links: Self-priming pump series Submersible sewage pump Submersible axial flow pump
Copyright © Hebei Yongquan Motor Pump Manufacturing Co., Ltd All Rights Reserved